C & I Air-cooling Cabinet Parameters

Model No. INEP5-125kW/215kWh
Grid/DG side parameters
Rated power 125kW
Maximum output power 137kW
Grid voltage 400V AC
Frequency range 50~60Hz
Rated AC current 180A @ 45°C
Can it operate off grid Yes
Other parameters
Grid connection type 3W+PE or 3W+N+PE
Off-grid conversion 20ms
Diesel engine starting mode I/O
Topological mode DC_Bus
PCS peak efficiency 99.73%
Overload capacity 110%, 1min; 120%, 10s
Fire fighting system Perfluorohexane/Aerosol
Battery system
System energy 215.04kWh
Battery type LFP-280Ah
Nominal voltage 768V
Operating voltage range 672V~864V
Max charge and discharge current 140A
PV system
Maximum input power 110kW
Maximum input current 300A
MPPT channels 4
MPPT power per channel/maximum power 30kW/35kW
Start-up voltage/Tracking voltage range DC 200V/DC 250V~650V
System Parameters
Cooling method Forced air cooling
Noise/Protection level <65dB/PS4
Operating humidity/Operating temperature 0-95% (no condensation)/-20°C~+60°C
Human-machine interface HMI/Cloud Platform
Installation method Outdoor-cabinet
Overall weight ≤2800kg
Dimension (WDH) 160012002200mm
Communication method RS485, CAN, Ethernet, dry contact
Altitude 4000m,<2000m Power reduced
Battery product certification IEC 62619, IEC 63056, IEC 60730, IEC/EN 61000, IEC 62477
PCS certification standards IEC 62477-1 & IEC 61000-6-2, VDE-AR-N 4105, NRS 097-21-1: 2017, GB/T34126-2017, GB/T34133-2017
Full container certification UN38.3

 

Off Grid Switching Cabinet Parameters

Model No. 2 parallel machines 5 parallel machines
Grid--DG side parameters
Rated power 250kW 625kW
Maximum output power 274kW 685kW
Grid voltage 400V AC 400V AC
Frequency range 50~60Hz 50~60Hz
Rated AC current 360A @ 45°C 900A @ 45°C
Other parameters
Grid connection type 3W+N+PE 3W+N+PE
Diesel engine starting mode I/O I/O
Overload capacity 110%, 1min; 120%, 10s 110%, 1min; 120%, 10s
STS parameters
Rated power 500kW 1250kW
Nominal voltage AC400V AC400V
Frequency range 50~60Hz 50~60Hz
Off-grid conversion 20ms 20ms
Switching device Thyristor Thyristor
Load side parameters
Rated power 250kW 625kW
Maximum output power 274kW 685kW
Grid voltage 400V AC 400V AC
Frequency range 50~60Hz 50~60Hz
Rated AC current 360A @ 45°C 900A @ 45°C
System Parameters
Cooling method Forced air cooling Forced air cooling
Noise/Protection level <65dB/PS4 <65dB/PS4
Operating humidity/Operating temperature 0-95% (no condensation)/-20°C~+60°C 0-95% (no condensation)/-20°C~+60°C
Human-machine interface HMI/Cloud Platform HMI/Cloud Platform
Installation method Outdoor-cabinet Outdoor-cabinet
Communication method RS485, CAN, Ethernet, dry contact RS485, CAN, Ethernet, dry contact
Altitude 4000m,<2000m Power reduced 4000m,<2000m P

 

Note: This specification is only suitable for Vietnam Market.

热门标签 :
留言
如果您对我们感兴趣并想了解更多详情,请在此留言,我们会尽快给您回复!
提交

相关产品

C & I Air-cooling Cabinet
C & I Air-cooling Cabinet
  更多的 +

注册以获得独家优惠和更新!

联系我们
支持热线 :+86 0592 2263666
联系电子邮件:sales@chinacnd.com
公司地址 :中国福建省厦门市思明区环岛东路1699号建发国际大厦19楼
© 厦门建发新兴能源有限公司 | 版权所有 | 网站地图 | 博客 | XML | 隐私政策

首页

产品

接触